Manufacturer website: www.se.com
PM3250

Manufacturer: Schneider
Product and variants: PM3250
Description: Panel three-phase electrical analyzer
Measures: Electrical parameters
Compatible using: DEXGate2
PM3255
Product and variants: PM3255
Description: Panel three-phase electrical analyser
Measures: Electrical parameters
Compatible using: DEXGate2
PM500
Manufacturer: Schneider
Product and variants: PM500
Description: Panel three-phase electrical analyzer
Measures: Electrical parameters
Compatible using: DEXGate2
(check attached file: PM500-userGuide)
PM5100
Manufacturer: Schneider
Product and variants: PM5100
Description: Panel three-phase electrical analyzer
Measures: Electrical parameters
Compatible using: DEXGate2
(check attached file: PM5100_User_Guide)
PM5300
Product and variants: PM5300
Description: Panel three-phase electrical analyzer
Measures: Electrical parameters
Compatible using: DEXGate2
PM5500
Product and variants: PM5500
Description: Panel three-phase electrical analyser
Measures: Electrical parameters
Compatible using: DEXGate2
Schneider PM710
Manufacturer: Schneider
Product and variants: PM710
Description: Panel three-phase electrical analyzer
Measures: Electrical parameters
Compatible using: DEXGate, EGX300
(check attached file: 710)
Schneider PM800
Manufacturer: Schneider
Product and variants: PM800
Description: Panel three-phase electrical analyser
Measures: Electrical parameters
Compatible using: DEXGate (It is necessary to enable Floating point registers), EGX300
(check attached files: pm800 and PM8xx_Enable_Float_Registers_from_Display)
Schneider PM9C
Manufacturer: Schneider
Product and variants: PM9C
Description: DIN-rail three-phase energy analyser
Measures: Electrical parameters
Compatible using: DEXGate, Schneider EGX300, Satel Owasys
Schneider PM9C quick install guide
To follow this guide you will need:
- 1 x DEXGate
- 1 x PM9C
- 1 x USB-RS485 adapter
- 1 x Computer
- 1 x Ethernet Cable
Installation:
- Install the current transformers following the following diagram:
- Connect the orange USB cable to the D1 B/B' connector, the yellow cable to the D0 A/A' connector and the black cable to the 0V connector:
- Power up the meter
- Access to set up menu (pass: 0010)
- Reset meter values
- Select connection scheme
- Configure current transformers factor
- Verify bus speed (by default: 19200)
- Configure ModBus address
- Power up the DEXGate
- Connect the USB-RS485 cable to the DEXGate
- Connect the Ethernet cable to your computer and the ETH1 port of the DEXGate
- Access the web administration interface of the DEXGate (http://172.16.0.1)
- Log in (the default username and password are admin/admin)
- Go to the "Bridge Configuration" section
- Edit the line:
devices.schneider-pm9c=
to look like this:devices.schneider-pm9c=10
- where "10" indicates ModBus meter address
- Save
- Restart the Modbus bridge or the DEXGate
- You're done!
(check attached file: pm9c)
SIM Series
Manufacturer: Schneider
Product and variants: SIM Series. Smart Interface Module.
Description: Smart Interface Modules provide local physical interfaces with buildings pulse output meters (water, gas, electricity, ...) and analog inputs.
Measures: pulses and analog inputs.
Compatible using: DEXGate2
(check attached file: SIM_series)