Socomec - Meters & Sensors

Follow

List of Socomec meters/sensors compatible with DEXGate or DEXGate 2:

  1. COUNTIS ECi3
  2. Digiware i30
  3. Digiware i33
  4. Digiware i60
  5. Digiware U10
  6. Socomec Countis E30
  7. Socomec Countis E40
  8. Socomec Countis E50
  9. Socomec Countis E60
  10. Socomec Countis ECi2
  11. Socomec Diris A10
  12. Socomec Diris A20
  13. Socomec Diris A40

 

1. COUNTIS ECi3



Manufacturer: Socomec
Product and variants: Countis ECi3
Description: Pulse acumulator with 7 pulse inputs
Measures: Digital pulses
Compatible using: DEXGate (Using USB COM-PRO or  USB-COMi-M Modbus conversors).
Compatible using: DEXGate2 Only if RS-485 bus impedance is well-adjusted (120ohm) or a/several Digiware device/s are present in the bus (see this article about RS485 bus: https://support.dexma.com/hc/en-gb/articles/360007866054  )

(check attached fle: COUNTIS_ECi3)

2. Digiware i30

Manufacturer: Socomec
Product and variants: Digiware i30
Description: Three channels current module for DIRIS Digiware modular monitoring system. For three single-phase or one three-phase.
Measures: Electrical parameters
Compatible using: DEXGate2
Commments: Requires C31 or D50 for communication, and U10 for voltage measures. 
Digiware connection example:

Click to buy! Special discounts!

(chech the attached files: catalogue_dirisdigiware-gbdiris_digiware_ENQuick_Start_diris_digiware)

3. Digiware i33

Manufacturer: Socomec
Product and variants: Digiware i33
Description: Three channels current module for DIRIS Digiware modular monitoring system. For three single-phase or one three-phase.
In addition to i30 capabilities, i33 adds THDi, P, Q, S, and PF per phase.

Measures: Electrical parameters
Compatible using: DEXGate2
Commments: Requires C31 or D50 for communication, and U10 for voltage measures. 
Digiware connection example:

(chech the attached files: catalogue_dirisdigiware-gbdiris_digiware_ENQuick_Start_diris_digiware)

4. Digiware i60

Manufacturer: Socomec
Product and variants: Digiware i60
Description: Six channels current module for DIRIS Digiware modular monitoring system. For six single-phase or two three-phase.
Measures: Electrical parameters
Compatible using: DEXGate2
Commments: Requires C31 or D50 for communication, and U10 for voltage measures. 
Digiware connection example:

Click to buy! Special discounts!

(chech the attached files: catalogue_dirisdigiware-gbdiris_digiware_ENQuick_Start_diris_digiware)

5. Digiware U10

 


Manufacturer: Socomec
Product and variants: Digiware u10
Description: Voltage Module for DIRIS Digiware modular monitoring system. 
Measures: Electrical parameters
Compatible using: DEXGate2
Commments: Requires C31 or D50 for communication, and i30 or i60 for current measures. 
Digiware connection example:



 

Click to buy! Special discounts!

6. Socomec Countis E30

 



Manufacturer: Socomec
Product and variants: Countis E30
Description: Three-phase DIN-rail energy meter
Measures: Electrical parameters
Compatible using: DEXGate (Using USB COM-PRO or  USB-COMi-M Modbus conversors)

Compatible using: DEXGate2 Only if RS-485 bus impedance is well-adjusted (120ohm) or a/several Digiware device/s are present in the bus (see this article about RS485 bus: https://support.dexma.com/hc/en-gb/articles/360007866054 )
Comments: This device supports direct currents up to 100A
 

7. Socomec Countis E40

 



Manufacturer: Socomec
Product and variants: Countis E40
Description: Three-phase DIN-rail energy meter
Measures: Electrical parameters
Compatible using: DEXGate (Using USB COM-PRO or  USB-COMi-M Modbus conversors)

Compatible using: DEXGate2 Only if RS-485 bus impedance is well-adjusted (120ohm) or a/several Digiware device/s are present in the bus (see this article about RS485 bus: https://support.dexma.com/hc/en-gb/articles/360007866054)
 

8. Socomec Countis E50

 



Manufacturer: Socomec
Product and variants: Countis E50
Description: Three-phase panel energy meter
Measures: Electrical parameters
Compatible using: DEXGate (Using USB COM-PRO or  USB-COMi-M Modbus conversors)

Compatible using: DEXGate2 Only if RS-485 bus impedance is well-adjusted (120ohm) or a/several Digiware device/s are present in the bus (see this article about RS485 bus: https://support.dexma.com/hc/en-gb/articles/360007866054)
 

9. Socomec Countis E60

 



Manufacturer: Socomec
Product and variants: Countis E60
Description: Three-phase DIN-rail energy meter
Measures: Electrical parameters
Compatible using: DEXGate (Using USB COM-PRO or  USB-COMi-M Modbus conversors)

Compatible using: DEXGate2 Only if RS-485 bus impedance is well-adjusted (120ohm) or a/several Digiware device/s are present in the bus (see this article about RS485 bus: https://support.dexma.com/hc/en-gb/articles/360007866054 )
Comments: This device supports direct currents up to 100A
 

10. Socomec Countis ECi2

 



Manufacturer: Socomec
Product and variants: Countis ECi2
Description: Pulse acumulator with 7 pulse inputs
Measures: Digital pulses
Compatible using: DEXGate (Using USB COM-PRO or  USB-COMi-M Modbus conversors).

Compatible using: DEXGate2 Only if RS-485 bus impedance is well-adjusted (120ohm) or a/several Digiware device/s are present in the bus (see this article about RS485 bus: https://support.dexma.com/hc/en-gb/articles/360007866054)
 

11. Socomec Diris A10

 



Manufacturer: Socomec
Product and variants: Diris A10
Description: Three-phase DIN-rail energy analyzer
Measures: Electrical parameters
Compatible using: DEXGate (Using USB COM-PRO or  USB-COMi-M Modbus conversors)

Compatible using: DEXGate2 Only if RS-485 bus impedance is well-adjusted (120ohm) or a/several Digiware device/s are present in the bus (see this article about RS485 bus: https://support.dexma.com/hc/en-gb/articles/360007866054 )
Comments: This device requires the resistors in the first and last device of the rs485 bus
 

Socomec Diris A10 - Quick Start Guide

 

To follow this guide you will need:

  • 1 x DEXGate
  • 1 x DIRIS A-10
  • 1 x USB-RS485 addapter
  • 1 x Computer
  • 1 x Ethernet Cable

Installation:

  1. Install the current transformers following the following diagram:
  2. Connect the orange usb cable to the 17 connector, the yellow cable to the 15 connector and the black cable to the 13 connector:
  3. Power up the meter
  4. Access to set up menu (pass code: 100)
  5. Select connection type and Configure current transformers factor
  6. Reset meter values
  7. Configure ModBus address
  8. Power up the DEXGate
  9. Connect the USB-RS485 cable to the DEXGate
  10. Connect the Ethernet cable to your computer and the ETH1 port of the DEXGate
  11. Access the web administration interface of the DEXGate (http://172.16.0.1)
  12. Login (the default username and password are admin/admin)
  13. Go to the "Bridge Configuration" section
  14. Edit the line:
    devices.socomec-a10=
    to look like this:
    devices.socomec-a10=10
  15. where "10" indicates ModBus meter adress
  16. Save
  17. Restart the modbus bridge or the DEXGate
  18. You're done!

12. Socomec Diris A20



Manufacturer: Socomec
Product and variants: Diris A20
Description: Three-phase panel energy analyzer
Measures: Electrical parameters
Compatible using: DEXGate (Using USB COM-PRO or  USB-COMi-M Modbus conversors)

Compatible using: DEXGate2 Only if RS-485 bus impedance is well-adjusted (120ohm) or a/several Digiware device/s are present in the bus (see this article about RS485 bus: https://support.dexma.com/hc/en-gb/articles/360007866054)
Comments: This device requires the resistors in the first and last device of the rs485 bus
 

13. Socomec Diris A40

 



Manufacturer: Socomec
Product and variants: Diris A40
Description: Three-phase panel energy analyzer
Measures: Electrical parameters
Compatible using: DEXGate (Using USB COM-PRO or  USB-COMi-M Modbus conversors)

Compatible using: DEXGate2 Only if RS-485 bus impedance is well-adjusted (120ohm) or a/several Digiware device/s are present in the bus (see this article about RS485 bus: https://support.dexma.com/hc/en-gb/articles/360007866054 )
Comments: This device requires the resistors in the first and last device of the rs485 bus

 